×÷ΪÖйúµÚÈý·½¼ì²âÓëÈÏÖ¤·þÎñµÄ¿ªÍØÕߺÍÁìÏÈÕߣ¬CTI9888À˹ά¼Ó˹¼ì²âΪȫÇò¿Í»§ÌṩһվʽĥÁ·¡¢²âÊÔ¡¢Ð£×¼¡¢ÈÏÖ¤¼°ÊÖÒÕ·þÎñ¡£
·þÎñÄÜÁ¦ÒÑÖÜÈ«ÁýÕÖµ½·ÄÖ¯´ò°ç¼°Ð¬°ü¡¢Ó¤Í¯Íæ¾ß¼°¼Ò¾ÓÉúÑÄ¡¢µç×ÓµçÆ÷¡¢Ò½Ñ§¿µ½¡¡¢Ê³Îï¼°Å©²úÆ·……µÈÐÐÒµµÄ¹©Ó¦Á´ÉÏÏÂÓΡ£
ÖÜÈ«°ü¹ÜÆ·ÖÊÓëÇå¾²£¬Íƶ¯ºÏ¹æÓëÁ¢Ò죬ÕÃÏÔÆ·ÅƾºÕùÁ¦£¬ÊµÏÖ¸ü¸ßÖÊÁ¿¡¢¸ü¿µ½¡¡¢¸üÇå¾²¡¢¸üÂÌÉ«µÄ¿ÉÒ»Á¬Éú³¤¡£
Ê×Ò³ > ÎÒÃǵķþÎñ > Ò½Ò©¼°Ò½Ñ§·þÎñ > Ò½ÁÆÆ÷е¼ì²â > ·þÎñÏêÇé
CTI9888À˹ά¼Ó˹¼ì²âΪÄúÌṩÐĵçͼ»ú×¢²á¼ì²â,ÓµÓйú¼ÒCNAS/CMA×ÊÖÊ,¿ÉΪÐĵçͼ»ú²úÆ·ÉÏÊÐÌṩרҵµÄ²âÊÔ¡¢Ä¥Á·¡¢ÉóºË¡¢×ÉѯµÈһվʽÊÖÒÕ·þÎñ¡£ÖúÁ¦Ðĵçͼ»ú²úÆ·ºÏ¹æ£¬¼øÖ¤ÖÊÁ¿Çå¾²£¬¿ÉÁýÕֵļì²â·þÎñ¹æÄ£ÓУºµçÆøÇå¾²¡¢µç´Å¼æÈÝ¡¢Ðĵçͼ»ú²úÆ·±ê×¼¡¢ÇéÐÎÊÔÑé¡¢ÉúÎïѧÆÀ¼Û¡¢Èí¼þ²âÆÀ¡¢Ï´åªÏû¶¾Ãð¾úÑéÖ¤¡¢°ü×°ÔËÊäµÈ²âÊÔ·þÎñ¡£
Σº¦Æ·¼¶·ÖÀà
ÔÚÎÒ¹úÒ½ÁÆÆ÷еע²á¹ÜÀíÖУ¬Ðĵçͼ»úΣº¦Æ·¼¶¹ÜÀíÖÖ±ðΪIIÀࣻ·ÖÀà±àÂëΪ07-03-01£»
Ðĵçͼ»ú×¢²á¼ì²â
CTI9888À˹ά¼Ó˹¼ì²â¿ÉÒÔΪÄúÌṩ¡¾Ðĵçͼ»ú¡¿Ò»Õ¾Ê½×¢²á¼ì²â½â¾ö¼Æ»®£¬¿ÉÁýÕֵļì²â·þÎñ¹æÄ£ÓУºµçÆøÇå¾²¡¢µç´Å¼æÈÝ¡¢Ðĵçͼ»ú²úÆ·±ê×¼¡¢ÇéÐÎÊÔÑé¡¢ÉúÎïѧÆÀ¼Û¡¢Èí¼þ²âÆÀ¡¢Ï´åªÏû¶¾Ãð¾úÑéÖ¤¡¢°ü×°ÔËÊäµÈ²âÊÔ·þÎñ¡£
Ðĵçͼ»ú²âÊÔ±ê×¼
²âÊÔÏîÄ¿ |
±ê×¼ |
±ê×¼Ãû³Æ |
°²¹æ | GB 9706.1-2020£»IEC 60601-1:2005/COR3:2022 | Ò½ÓÃµçÆø×°±¸ µÚ1²¿·Ö£ºÇ徲ͨÓÃÒªÇó |
GB 9706.225-2021£»IEC 60601-2-25:2011 | Ò½ÓÃµçÆø×°±¸ µÚ2-25 ²¿·Ö£ºÐĵçͼ»úµÄ»ù±¾Çå¾²ºÍ»ùÌìÐÔÄÜרÓÃÒªÇó | |
YY 9706.247-2021£»IEC 60601-2-47:2012£»ANSI/AAMI EC38:2007 | Ò½ÓÃµçÆø×°±¸ µÚ 2 ²¿·Ö:¶¯Ì¬ÐĵçͼϵͳÇå¾²ºÍ»ùÌìÐÔÄÜרÓÃÒªÇó | |
YY 0782-2010£»IEC 60601-2-51:2003 | Ò½ÓÃµçÆø×°±¸ µÚ2-51²¿·Ö£º¼Í¼ºÍÆÊÎöÐ͵¥µÀºÍ¶àµÀÐĵçͼ»úÇå¾²ºÍ»ùÌìÐÔÄÜרÓÃÒªÇó | |
YY 1139-2013£»ANSI/AAMI EC11:1991/(R)2001/(R)2007 | ÐĵçÕï¶Ï×°±¸ | |
YY/T 0196-2005 | Ò»´ÎÐÔʹרÐĵçµç¼« | |
YY 0828-2011£»ANSI/AAMI EC53-2013 | Ðĵç¼à»¤ÒǵçÀº͵¼ÁªÏß | |
EMC | YY 9706.102-2021£»IEC60601-1-2:2014+A1:2020 | Ò½ÓÃµçÆø×°±¸ µÚ1-2²¿·Ö£ºÇ徲ͨÓÃÒªÇó ²¢Áбê×¼£ºµç´Å¼æÈÝÒªÇóºÍÊÔÑé |
ÇéÐÎÊÔÑé | GB/T 14710-2009 | Ò½ÓõçÆ÷ÇéÐÎÒªÇó¼°ÊÔÑéÒªÁì |
ÉúÎïѧÆÀ¼Û | GB/T 16886.1-2022 | Ò½ÁÆÆ÷еÉúÎïѧÆÀ¼Û µÚ1²¿·Ö£ºÎ£º¦¹ÜÀíÀú³ÌÖÐµÄÆÀ¼ÛÓëÊÔÑé |
GB/T 16886.5-2017 | Ò½ÁÆÆ÷еÉúÎïѧÆÀ¼Û µÚ5²¿·Ö£ºÌåÍâϸ°û¶¾ÐÔÊÔÑé | |
GB/T 16886.10-2017 | Ò½ÁÆÆ÷еÉúÎïѧÆÀ¼Û µÚ10²¿·Ö£º´Ì¼¤Óë³Ù·¢Ðͳ¬Ãô·´Ó¦ÊÔÑé | |
ISO 10993-1:2018 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process | |
ISO 10993-5:2009 | Biological evaluation of medical devices Part 5: Tests for in vitro cytotoxicity | |
ISO 10993-10:2021 | Biological evaluation of medical devices Part 10: Tests for skin sensitization | |
ISO 10993-23:2021 | Biological evaluation of medical devices Part 23: Tests for irritation | |
Ï´åªÏû¶¾Ãð¾úÑéÖ¤ | GB 18280.2/ISO11137-2 | ·øÉäÃð¾ú¼ÁÁ¿É趨 |
GB/T 16886.7/ ISO 10993-7/GB/T 14233.1 | »·ÑõÒÒÍéÃð¾ú²ÐÁôÁ¿£¨EO/ECH£© | |
WS 310.1/WS 310.2/WS 310.3/WS/T 367/GB 18278.1/AAMI TIR30:2011/(R)2016/ AAMI TIR 12-2020/ASTM F3208-20/ ISO 17664/ISO 20857/ISO 25424/ YY/T 0734/ YY/T 1495 | Ï´åªÏû¶¾Ãð¾úÑéÖ¤ | |
Èí¼þ¼°²âÆÀ | GB/T 25000.51 | ¡¶ÏµÍ³ÓëÈí¼þ¹¤³ÌϵͳÓëÈí¼þÖÊÁ¿ÒªÇóºÍÆÀ¼Û£¨SQuaRE£©µÚ51²¿·Ö£ºÍ£µ±¿ÉÓÃÈí¼þ²úÆ·£¨RUSP£©µÄÖÊÁ¿ÒªÇóºÍ²âÊÔϸÔò¡· |
GB/T 25000.10 | ¡¶ÏµÍ³ÓëÈí¼þ¹¤³ÌϵͳÓëÈí¼þÖÊÁ¿ÒªÇóºÍÆÀ¼Û£¨SQuaRE£©µÚ10²¿·Ö£ºÏµÍ³ÓëÈí¼þÖÊÁ¿Ä£×Ó | |
YY/T 1843-2022 | Ò½ÓÃµçÆøÏµÍ³¼°Ò½ÁÆÆ÷еÈí¼þµÄÍøÂçÇå¾²»ù±¾ÒªÇó | |
ÎÞ¾úÒ½ÁÆÆ÷°ü×°ÑéÖ¤ | GB/T 19633.1/ISO 11607-1/YY/T0681.1-/ASTMF1980-16 | ¼ÓËÙÀÏ»¯ÊÔÑé |
GB/T 19633.1/ISO 11607-1/GB/T 19633.2/ISO 11607-2/YY/T0681.2/ASTM F88/F88M-15 | ·â¿Ú°þÀëÊÔÑ飨ÃÜ·âÇ¿¶È£© | |
YY/T 0681.3-2010/ASTMF1140/F1140M-13 | ÕÇÆÆÊÔÑéºÍÈä±äÊÔÑé | |
YY/T 0681.4-2021/ASTMF1929-15 | ȾÁÏÉøÍ¸ÊÔÑ飨ÃÜ·âй¶£© | |
GB/T 19633.1/ISO 11607-1/YY/T 0681.5-/ASTMF2096/YY/T0681.9/ASTMF2054/F2054M | Õæ¿Õй¶ÊÔÑé | |
YY/T 0681.9 | ÃÜ·âÕÇÆÆÊÔÑé | |
YY/T0681.11/ASTMF1886/F1886M | Ä¿ÊÓÊÔÑé | |
YY/T 0681.14/ ISO 11607-1/DIN 58953-6/GB/T 19633.1/Ïû¶¾ÊÖÒչ淶 | ΢ÉúÎïÆÁÕϼì²â | |
ÖйúÒ©µä | 𤸽Á¦²â¶¨·¨(³õð¤Á¦µÄ²â¶¨) | |
°ü×°ÔËÊäÑéÖ¤ | GB/T 4857 ASTM D4169ϵÁУ»ISTAϵÁÐ | °ü×°ÔËÊä |
ÎÂܰÌáÐÑ£ºÊö±ê×¼Ö»ÁÐÉú²úÆ·ÊÖÒÕÒªÇóÖо³£Éæ¼°µ½µÄ±ê×¼£¬²¢·ÇËùÓбê×¼¡£
ͨÀýÑùÆ·ÒªÇó
ÍêÕûÄÜÕý³£ÊÂÇéµÄÑù»ú£¬ÆäËûÏêϸÏêÇéÇë×ÉѯCTIÔÚÏ߿ͷþ¡£
ÎÒÃǵÄÓÅÊÆ
1¡¢CTI¾ßÓÐרҵ×ÊÖÊ¡¢ÂÄÀú¸»ºñµÄÊÖÒÕר¼ÒÍŶӣ¬ÎªÄúÌṩרҵ×ÉѯºÍ·þÎñ¡£
2¡¢CTIÓµÓÐÏȽøµÄʵÑéÊÒ×°±¸£¬È·±£²âÊÔÊý¾ÝµÄ׼ȷºÍ¿É¿¿¡£
3¡¢CTI×÷ΪȫÇò¿Í»§ÐÅÈεĵÚÈý·½²âÊÔÈÏÖ¤»ú¹¹£¬ÎÒÃÇÊÇÄúÆ·Öʵı³Êé¡£
4¡¢ÎÒÃÇÒÀ¸½±é²¼È«ÇòµÄʵÑéÊÒÍøÂ磬ΪÄúÌṩÖÜÈ«ÍêÉÆµÄһվʽ²âÊÔÈÏÖ¤½â¾ö¼Æ»®¡£
³£¼ûÎÊÌâ
CTIµÄÒ½ÁÆÆ÷е¼ì²âµÄ²âÊÔÖÜÆÚÊǶà¾Ã£¿
ÏÖʵÖÜÆÚÆ¾Ö¤Î¯ÍеIJúÆ·±ê×¼À´È·¶¨£¬ÇëÓëCTI¿Í·þÁªÏµÈ·ÈÏ¡£
CTIÒ½ÁÆÆ÷е¼ì²âµÄ²âÊÔÒªÁìÊÇʲô£¿
Õë¶Ô²úÆ·µÄ³ö¿ÚÒªÒÔ¼°¿Í»§Î¯ÍеÄÒªÇ󣬾ÙÐбê×¼¼ì²â¡£
CTI¹ØÓÚÑùÆ·µÄÁôÑùÖÜÆÚÊǶà¾Ã£¿
ÍËÑù¡£
·þÎñÁ÷³Ì